System health cluster switch power show.
Netapp 7 mode check power supply status.
Display detailed information about each shelf including the shelf s uuid and id its connected nodes and the number of paths to the shelf.
Use other parameters to filter the list of alerts for example by policy status enabled or not health monitor alert and so on.
System health system connectivity shelf show instance.
Use the instance parameter to display detailed information about each shelf.
Netapp active iq is a digital advisor that uses aiops to provide actionable insights and automate the proactive care and optimization of your netapp environment.
Commands for displaying environmental status the environment commands enable you to display all environment information shelf environment status and chassis environment status.
A lot of times these errors will cause a case to be generated but the standard response for those cases is to email the contact and ask them to inspect.
Physically unplug the cables from power supplies on the back of the storage systems and shelves to avoid any electrical issues when external power is restored.
Cluster1 storage shelf show module operational shelf name shelf id serial number model type status 1 1 1 6000270148 ds2246 iom6 critical 1 3 3 6000001183 ds2246 iom6 normal 1 4 4 6000003844 ds2246 iom6 normal 1 5 5 shj000000013a9e ds4246 iom6 normal 1 6 6 shj000000013a84 ds4246 iom6 normal 1 7 7 6000005555.
It looks like you have 2 shelves that have some type of issue.
Enter cf enable and monitor with cf status.
Read more launch aiq arrow forward.
The sp commands at the admin privilege level enable you to display events logs and status information for node power batteries sensors field replaceable units frus or the sp itself.
The commands also enable you to reboot the node or the sp and create a core dump.
The command environment status chassis only looks at the storage appliance itself its onboard power supplies and fans etc.
Downgrading software versions between minor releases when downgrading a cluster from data ontap 8 2 1 to data ontap 8 2 ontap clears the history of deleted switches.
For clustered ontap systems check cluster show and storage failover show to confirm cfo sfo is configured enabled.
This command is available to cluster administrators at the admin privilege level.
Display the status of shelves from the cluster level view including the shelf s uuid and id its connected nodes and the number of paths to the shelf system health system connectivity shelf show note.
For 7 mode ha pairs.
System health system connectivity shelf show.